Introducción: el tinnitus tiene efectos deletéreos sobre la calidad de vida de un paciente. Cuando la lesión está a nivel coclear, se puede usar acondicionamiento acústico para su tratamiento. Objetivo: determinar el cambio en la percepción del tinnitus antes y después de la intervención terapéutica. Metodología: se planteó un estudio de serie de casos. Pacientes con tinnitus no pulsátil de moderado a catastrófico tratados con estimulador REVE 134™. Se incluyeron pacientes que no mejoraron luego de 3 meses con tratamiento médico. Se les practicó microaudiometría (67 frecuencias) para definir la región coclear afectada. Se excluyeron pacientes con umbrales audiométricos > 60 dB, aquellos con lesiones retrococleares y quienes no desearon participar. Las variables de desenlace fueron Tinnitus Handicap Inventory (THI), escala visual análoga (EVA) y Tinnitus Reaction Questionnaire (TQR), que se midieron pretratamiento y a los 3 y 6 meses postratamiento. Resultados: se incluyeron 11 pacientes (hombres = 5, mujeres = 6). En 5 casos el tinnitus fue bilateral y en 6, unilateral. Los valores pretratamiento fueron THI = 61,4 ± 27,4, EVA = 6,9 ± 2,7 y TQR = 43,2 ± 31,9 (Kolmogorov-Smirnov, p > 0,05). Hubo mejoría estadísticamente significativa con el tratamiento, THI (3 meses = 30,6 ± 21,1; 6 meses = 19 ± 19,2), EVA (3 meses = 5,6 ± 2,3; 6 meses = 3,5 ± 2,0), TQR (3 meses = 25,6 ± 20,0; 6 meses = 14,3 ± 19,9); ANOVA de medidas repetidas (p = 0,007, p = 0,027, p = 0,037; respectivamente). Conclusión: el tratamiento con REVE 134™ fue efectivo en pacientes con tinnitus no pulsátil de moderado a catastrófico.


Introduction: tinnitus can affect the quality of life of a patient. Acoustic stimulation can be used as treatment when the cause of tinnitus is located in the cochlea. Objective: To determine changes in tinnitus perception before and after therapeutic intervention. Methodology: We performed a case series study. Patients with nonpulsatile tinnitus, with no improvement with medical therapy, and moderate to catastrophic grade were treated with the REVE 134™ system. A microaudiometry (67 frequencies) was performed to determine the cochlear regions affected. Patients with auditory thresholds >60 dB, retrocochlear pathologies and who did not want to participate in the study were excluded. The variables studied were Tinnitus Handicap Inventory (THI), Visual Analog Scale (VAS) and Tinnitus Reaction Questionnaire (TQR), that were measured before, three and six months after treatment. Results: 11 patients (male: 5, women: 6) were included. In 5 of them, tinnitus was bilateral and in 6, unilateral. Pretreatment values were: THI = 61.4 ± 27.4, VAS = 6.9 ± 2.7 and TQR = 43.2 ± 31.9 (Kolmogorov-Smirnov, p > 0.05). We found improvement in tinnitus perception with the therapy, and this values had statistical significance (THI: 3rd month = 30.6 ± 21.1; 6th month = 19 ± 19.2), VAS (3rd month = 5.6 ± 2.3; 6th month = 3.5 ± 2.0), TQR (3rd month = 25.6 ± 20.0; 6th month =14.3 ± 19.9); repetitive measures of ANOVA (p = 0.007, p = 0.027, p = 0.037; respectively). Conclusion: Treatment with REVE 134™ was effective in patients with moderate to catastrophic tinnitus.


Subject(s)
Humans , Tinnitus , Cochlea , Hearing Loss
2.
Acta otorrinolaringol. cir. cuello (En línea) ; 48(1): 62-68, 20200000. ilus, tab, graf
Article in Spanish | COLNAL, LILACS | ID: biblio-1097450

ABSTRACT

Objetivo: evaluar las diferencias en la percepción musical entre la estimulación sonora eléctrica frente a la acústica. Materiales y métodos: se recolectó información de pacientes adultos con implante coclear unilateral, con oído contralateral sano o hipoacusia leve y con un tiempo de rehabilitación auditiva mayor a 12 meses. Se les aplicaron escalas de reconocimiento musical, de calidad de vida Glasgow Benefit Inventory (GBI), identificación de tono, ritmo, instrumentos y canciones. Resultados y conclusiones: se recolectaron datos de 6 pacientes con edades entre 37-73 años, promedio de tonos puros (PTA, por sus siglas en inglés) en oído sano <40 dB y porcentaje de máxima discriminación (SDS, por sus siglas en inglés): 100 % sin cambios en el postoperatorio. El oído implantado con un rango de PTA postoperatorio entre 40 y 58,3 dB y SDS entre 70-90 %. Se aplicó la escala GBI, en donde la mayoría de los pacientes obtuvieron resultados positivos con un rango entre +41 y -13. La mayoría de los pacientes aumentaron la frecuencia de escucha musical post-implantación (4/6 pacientes). La mitad de los pacientes reportaron mejoría en el papel que desempeña la música en sus vidas. En el reconocimiento del tono y del ritmo en el oído implantado se encontraron resultados similares posterior a la implantación con respecto al oído sano, con medianas de 17/20 frente a 16/20 en patrones tonales y 18,5/20 frente a 18/20 en patrones rítmicos. El reconocimiento de las canciones fue mejor con la letra que sin la letra en el oído implantado (8/8 frente a 7/8, respectivamente). El reconocimiento de instrumentos en el oído implantado fue 4,5/8 instrumentos frente a 7,5/8 en el oído sano.


Objective: To evaluate the differences in musical perception between electrical and acoustic sound stimulation. Materials and methods: Adult patients with unilateral cochlear implant, healthy or mild hearing loss in the contralateral ear and rehabilitation time greater than 12 months were evaluated. Musical recognition scales, quality of life Glasgow Benefit Inventory (GBI) and identification of tone, rhythm, instruments, and songs were applied. Results and conclusions: 6 patients were collected, ages between 37-73 years, healthy ear with a pure tone average (PTA) <40 dB, speech discrimination score (SDS): 100 % without changes in the postoperative period. The Implanted ear with average PTA between 40­58.3 dB and SDS between 70-90 % post-implantation. The GBI scale was applied where most of the patients obtained positive results, with a range between +41 and -13. Most of the patients improved the frequency of music-listening after implantation (4/6 patients). Half of the patients reported improvement in the role music plays in their lives. In the recognition of the tone and rhythm in the implanted ear, similar results were found after the implantation with respect to the healthy ear, with medians of 17/20 vs. 16/20 in tonal patterns and 18.5/20 vs. 18/20 in rhythmic patterns. The recognition of the songs was better with the lyrics than without the lyrics in the implanted ear, with medians of 8/8 vs. 7/8. The recognition of instruments in the implanted ear was 4.5/8 vs. 7.5/8 in the healthy ear.


Subject(s)
Humans , Cochlear Implants , Auditory Perception , Hearing Loss, Sensorineural , Music
3.
Acta otorrinolaringol. cir. cabeza cuello ; 45(2): 112-120, 2017. graf, tab
Article in Spanish | LILACS, COLNAL | ID: biblio-969259

ABSTRACT

Objetivo: Evaluar la efectividad del programa de tamizaje auditivo del Hospital Militar Central en pacientes de alto riesgo de hipoacusia neurosensorial, el cual está basado en la realización de otoemisiones acústicas. Diseño: Estudio de Cohorte Histórica. Métodos: Se incluyeron pacientes mayores de 12 meses de edad nacidos en el Hospital Militar central entre enero de 2009 y diciembre de 2012; a quienes por condiciones de alto riesgo de hipoacusia neurosensorial se les realizó antes de los 6 meses de edad otoemisiones acústicas como prueba de tamizaje auditivo. Se analizaron 125 pacientes evaluando cada oído por separado para un total de 250 mediciones, a esta población, se le realizó diagnóstico auditivo con el "Gold standard" cross-check. Resultados: Se estudiaron los factores de riesgo para hipoacusia neurosensorial encontrando que el peso al nacer ≤1500 gr se relacionó con hipoacusia en un 16%. El 5.6% tiene antecedente familiar de hipoacusia neurosensorial en primer y segundo grado de consanguinidad. La infección congénita (STORCH: sífilis, toxoplasmosis, rubéola, citomegalovirus, herpes); como factor de riesgo se presentó en el 2.4% únicamente con la presencia de Toxoplasmosis, de los cuales 2 oídos presentaron cofosis. Conclusiones: Las otoemisiones acústicas son efectivas como prueba de tamizaje auditivo en el HOMIC en pacientes de alto riesgo de hipoacusia Neurosensorial. La sensibilidad de las Otoemisiones acusticas para sospechar hipoacusia neurosensorial de moderada a profunda fue del 93.7 % La especificidad estimada en nuestro estudio fue de 90.9%


Objective: To evaluate the effectiveness of the auditory screening program at the "Hospital Militar Central" in patients who were at high risk of sensorineural hearing loss, which is based on the realization of otoacoustic emissions. Design: Retrospective cohort study Methods: We included patients older than 12 months of age who were at "Hospital Militar Central" (HOMIC) between January 2009 and December; who ought to their high risk conditions of sensorineural hearing loss were underwent otoacoustic emissions and hearing screening test before 6 months of age. Total population was 125 patients. We evaluated each ear separately for a total of 250 measurements, an auditory diagnosis was performed through crosscheck method. Results: Risk factors for sensorineural hearing loss were studied. We found that birth weight ≤1500gr was associated with hearing loss by 16%. 5.6% have a family history of sensorineural hearing loss in first and second degree of consanguinity. Congenital infection (TORCHS: toxoplasmosis, syphilis, rubella, cytomegalovirus, or herpes) as a risk factor occurred in 2.4% only in the presence of Toxoplasmosis, of which 2 ears presented deafness. Conclusions: The otoacoustic emissions are effective as a hearing screening test in the "Hospital Militar Central" in patients at high risk of Sensorineural hearing loss. The sensitivity of otoacoustic emissions to suspect sensorineural hearing loss was 93.7%. The estimated specificity in our study was 90.9%


Subject(s)
Humans , Hearing Loss, Sensorineural , Infant, Newborn , Hearing , Hearing Disorders
4.
Acta otorrinolaringol. cir. cabeza cuello ; 43(2): 141-146, 20150000. tab
Article in Spanish | LILACS | ID: biblio-966432

ABSTRACT

Objetivo: Determinar si en pacientes con trauma facial que requieren tratamiento quirúrgico, el manejo tardío de la fractura nasal ofrece porcentajes de éxito diferentes a los ofrecidos por el manejo temprano. Diseño: Estudio tipo cohorte histórica (cohorte retrospectiva). Metodología: Se incluyeron todos los pacientes sometidos a intervención quirúrgica por fractura nasal debido a trauma de guerra. Los pacientes se asignaron a dos grupos de investigación. Grupo I, aquellos que recibieron cirugía temprana y Grupo II aquellos pacientes que recibieron tratamiento luego de tres semanas del trauma. Se calculó un tamaño de muestra de 55 pacientes por grupo. Los pacientes fueron evaluados clínicamente de forma ciega por dos especialistas para determinarl éxito o fracaso quirúrgico. Resultados: Se revisó los registros de historias clínicas de 175 pacientes asistentes al Hospital Militar Central que cumplieron criterios de inclusión, de estos, 32 fueron excluidos y 21 fueron asignados a una prueba piloto inicial. Se analizaron 122 pacientes en total divididos en dos grupos, Grupo I (n=67) y Grupo II (n=55). Evaluación ciega con una alta concordancia interevaluador (kappa =0.98). Se comparó la proporción de éxito quirúrgico entre los dos grupos sin encontrar diferencias estadísticamente significativas (chi 2 Pearson p=0.97). Conclusión: En el contexto del trauma de guerra, la decisión de llevar a un paciente de trauma nasal a un manejo de forma temprana o tardía dependerá de muchos factores inherentes al conflicto armado. La oportunidad en el manejo quirúrgico según los hallazgos del presente estudio, no interviene en la probabilidad de éxito quirúrgico.


Objective: To determine whether patients with facial trauma requiring surgical treatment, late nasal fracture management provides success rates different to those offered by earlier operation. Study design: Historical cohort study (retrospective cohort). Methodology: All patients undergoing surgery for nasal fracture due to war trauma were included. Patients were assigned to one of two groups. Group I, those who received early surgery and Group II those patients who received treatment after three weeks of trauma. A sample size of 55 patients per group was calculated. The evaluation was blind by two service specialists to determine failure or success of the surgery. Results: 175 medical records of patients attending the Central Military Hospital who met inclusion criteria were reviewed. Of these, 32 were excluded and 21 were assigned to an initial pilot study. A total of 122 patients divided in two groups; Group I (n=67) and Group II (n=55) were analyzed. Two raters evaluated the subjects blindly with a high concordance inter-rater (kappa = 0.98). The proportion of surgical success between the two groups was compared; we found no statistically significant difference between the two groups (Pearson chi 2 p = 0.97). Conclusion: In the context of the trauma of war, the decision to refer a patient to a nasal trauma management how early or late will depend on many factors inherent in armed conflict. The opportunity in the surgical management according to the findings of this study, is not involved in the probability of surgical success.


Subject(s)
Nose Deformities, Acquired , Nasal Surgical Procedures , Maxillofacial Injuries , Military Personnel
6.
Rev. MED ; 22(2): 20-31, jul.-dic. 2014. ilus
Article in Spanish | LILACS | ID: lil-760074

ABSTRACT

Objetivo: Determinar si pacientes con perforación timpánica causada por trauma por onda explosiva tienen un resultado quirúrgico peor que el encontrado en pacientes con perforación timpánica causada por otitis media crónica. Metodología: Estudio observacional analítico tipo cohorte prospectiva. Se comparó los resultados en timpanoplastia tipo I entre pacientes expuestos a trauma por onda explosiva (cohorte expuesta) y pacientes con perforación causada por otitis media crónica (cohorte no expuesta). Se incluyeron pacientes mayores de 18 años en quienes se utilizó técnica “over-under” de colocación de injerto de cartílago. Se excluyeron pacientes en quienes se utilizó otras técnicas quirúrgicas, a quienes se les practicó mastoidectomia u osciculoplastia, aquellos con perforaciones secundarias a otra etiología y quienes tenían colesteatoma. El tamaño de la muestra se calculó para la variable resultado anatómico y fue de 43 pacientes por cohorte. El estudio se terminó una vez se consiguió el tamaño de muestra propuesto. El análisis principal fue la comparación del resultado anatómico (estado del neo tímpano) y funcional (brecha aíre-hueso <10dB) entre las cohortes expuesta y no expuesta. Resultados: El estudio inició en agosto1 de 2011 y finalizó en julio 25 de 2013. No se encontró asociación entre la exposición bajo estudio y el fracaso anatómico, RR=4.0 [IC 95% RR = 0.47- 34.35]. Tampoco hubo asociación entre el fracaso anatómico y perforación timpánica ≥50%, localización anterior de la perforación timpánica e inflamación /infección al momento de la cirugía [IC 95% RR incluyó el valor 1]. Los pacientes de la cohorte expuesta tuvieron un RR=1.76 de fracaso funcional [IC 95% RR=1.19-2.59]. Conclusiones: El resultado anatómico de la timpanoplastia tipo I es equiparable entre los pacientes con perforación timpánica secundaria a trauma por onda explosiva respecto a aquellos con perforaciones timpánicas por otitis crónica. Sin embargo se observó un peor resultado funcional entre los pacientes víctimas de trauma por onda explosiva.


Objective: To determine whether patients with perforated eardrum caused by blast injury have a worse surgical outcome than that found in patients with perforated eardrum caused by chronic otitis media Methods: This is a prospective cohort study. We compared the results in type I tympanoplasty in patients exposed to blast injury (exposed cohort), and patients with perforation caused by chronic otitis media (unexposed cohort). We included patients older than 18 years in whom the over-under tympanoplasty technique was used, using cartilage graft. We excluded patients who underwent other surgical techniques, who underwent mastoidectomy and/or osciculoplastia, those with perforations secondary to other etiologies and those with cholesteatoma. The sample size was calculated for the variable anatomical outcome, and it was 43 patients per cohort. The study was finished once we reached the proposed sample size. The main outcome was the comparison of the anatomical outcome (status of the eardrum) and the functional outcome (air-bone gap <10 dB), between the exposed and unexposed cohorts. Results: The study began in August 1, 2011 and ended on July 25, 2013. There was no association between the exposure under study and the anatomical failure, RR=4.0 [IC 95% RR = 0.47-34.35]. There was also no association between the anatomical outcome and size of the perforated eardrum ≥ 50%, anterior tympanic membrane perforation and inflammation/infection at the time of surgery [IC 95%RR included the value 1]. The patients of the exposed cohort had a RR = 1.76 for functional failure, [IC 95% RR=1.19-2.59]. Conclusions: The anatomical outcome of type I tympanoplasty is comparable between patients with tympanic membrane perforation secondary to blast injury compared to those with chronic otitis media. However, we found a worse functional outcome among patients suffering from blast injury.


Objetivo: Avaliar se os pacientes com perfuração timpânica causada pelo trauma por onda explosiva tem um resultado cirúrgico pior do que os pacientes com perfuração timpânica causada pela otites media crônica. Metodologia: Estudo observacional analítico prospectivo. Foram comparados os resultados em timpanoplastia tipo I entre pacientes expostos ao trauma por onda explosiva (grupo exposto) e pacientes com perfuração por otites media crônica (grupo não exposto). Foram incluídos pacientes maiores de 18 anos utilizando a técnica “over-under” de colocação de implante de cartilagem. Foram excluídos os pacientes que utilizaram outras técnicas cirúrgicas, mastoidectomia ou ossiculoplastia, aqueles com perfurações secundarias a outra etiologia e os que tinham colesteatoma. O tamanho dà amostra foi calculada para a variável resultado anatômico e foi de 43 pacientes por grupo. O Estudo finalizou no momento que a amostra foi atingida. O análise principal foi a comparação do resultado anatômico (estado do neo-timpano) e funcional (lacuna aire-osso<10dB) entre os grupos exposto e não exposto. Resultados: O estudo inicio o primeiro de agosto de 2011 e finalizou o 25 de junho de 2013. Não se apresentou associação entre a explosão no estudo e o fracasso anatômico, RR=4.0 [IC 95% RR = 0.47-34.35]. Além disso, não houve associação entre o fracasso anatômico e perfuração timpânica ≥50%, localização anterior da perfuração timpânica e inflamação/infecção ao momento do procedimento cirúrgico [IC 95% RR incluiu o valor 1]. Os pacientes do grupo exposto tiveram um RR=1.76 de fracasso funcional [IC 95% RR=1.19-2.59]. Conclusões: O resultado anatômico da timpanoplastia tipo I é equiparável entre os pacientes com perfuração timpânica secundaria ao trauma por onda explosiva quanto a aqueles com perfurações timpânicas por otites crônica. Embora, foi observado um pior resultado funcional entre os pacientes vítimas de trauma por onda explosiva.


Subject(s)
Adult , Hearing Loss, Noise-Induced , Myringoplasty , Otitis Media , Tympanic Membrane Perforation , Tympanoplasty
9.
Acta otorrinolaringol. cir. cabeza cuello ; 40(1): 19-26, ene.-mar. 2012. ilus
Article in Spanish | LILACS | ID: lil-682771

ABSTRACT

Objetivo: Comparar los resultados de timpanoplastia entre fascia temporal (GI) y cartílago auricular (GII) en perforación timpánica secundaria a trauma por onda explosiva. Diseño: Estudio de cohorte histórica. Métodos: Se incluyeron pacientes llevados a timpanoplastia tipo I, intervenidos entre febrero 1.º del 2007 y diciembre 31 del 2009. Los sujetos son miembros de las Fuerzas Armadas de Colombia, heridos en combate. Fueron excluidos aquellos sometidos a mastoidectomía u osciculoplastia. El resultado anatómico se evaluó mediante prueba exacta de Fisher, y el funcional, mediante Anova. Resultados: Se incluyeron 36 sujetos, GI = 16 y GII = 20. No hubo diferencias en el éxito anatómico entre GII = 95% (19/20) y GI = 87,5% (14/16), a los 12 meses (p = 0,57). En pacientes con cadena íntegra-móvil, la brecha aire-hueso a los seis meses (n = 30) fue de 5,8 dB (DE = 8 dB), y a los doce meses (n = 26) fue de 5,4 dB (DE = 8 dB). No hubo asociación entre el resultado funcional y el tipo de injerto utilizado (p > 0,05). Conclusiones: la timpanoplastia en perforación secundaria a trauma por onda explosiva ofrece resultados satisfactorios y estables a los doce meses, tanto con fascia como con cartílago...


Objective: to compare tympanoplasty outcomes between fascia temporalis (GI) and auricular cartilage (GII) in tympanic membrane perforation caused by blast injury. Design: historical cohort study. Methods: patients underwent tympanoplasty type I, between February 1-2007 and December 31-2009, were included. The study subjects are members of the armed forces of Colombia that were wounded in combat. Patients who underwent mastoidectomy or ossiculoplasty were excluded. The Fisher’s exact test was performed to assess the anatomical outcome, and the ANOVA test to assess the functional outcome. Results: 36 subjects were included, GI = 16 and GII = 20. Regarding the anatomical success, there was no differences between GI = 95% (19/20) and GII = 87.5% (4/16), at 12 months of follow-up (p = 0.57). In patients with an intact ossicular chain, the airbone gap at 6 months (n = 29) was = 5.8 dB (SD = 8 dB); while at 12 months (n = 26) it was = 5.4 dB (SD = 8 dB). There was no relationship between the functional outcome and the kind of graft used (p > 0.05). Conclusions: the surgical outcomes of the tympanoplasty in tympanic membrane perforation caused by blast injury are satisfactory and stable at 12 months, with fascia and cartilage...


Subject(s)
Humans , Myringoplasty , Tympanic Membrane Perforation , Hearing Loss, Noise-Induced , Hearing Loss, Noise-Induced/diagnosis , Tympanoplasty
10.
Acta otorrinolaringol. cir. cabeza cuello ; 40(4): 301-310, 2012. ilus
Article in Spanish | LILACS | ID: lil-692125

ABSTRACT

Objetivos: Revisar/resumir indicaciones, resultados audiológicos y de calidad de vida del dispositivo totalmente implantable Carina®. Diseño: Revisión sistemática. Métodos: Se realizó una búsqueda sistemática de la literatura entre junio/2011 y enero/2012 en bases de datos: Medline, OVID, Embase, Pro Quest, Biblioteca Cochrane. También se revisó literatura gris (Sigle) en búsqueda de información no publicada. No hubo restricción de lenguaje o límite temporal, y se incluyeron estudios en humanos con mediciones antes/después de la intervención. Se excluyeron reportes de un caso y estudios con pacientes prelinguales. Se evaluó heterogeneidad estadística (prueba Der Simonian-Laird), y la ganancia funcional combinada (GFC) se estimó con un modelo de efectos aleatorios. Se evaluó sesgo de publicación (gráfica de embudo y prueba Eggs). Resultados: Se identificaron 155 publicaciones, 43 enfocadas en el tema de investigación; ocho cumplieron criterios de inclusión/exclusión, que reportan 110 pacientes. La GFC fue 27,24 dB [IC 95% = 21,66-32,83 dB], I2 = 85%. El reconocimiento de palabras (65 dB-SPL) se incrementó con Carina® entre 35 y 70%, y hubo mejoría en calidad de vida (escala Aphab). La complicación más frecuente fue extrusión (2,7%). Se encontró sesgo de publicación (Eggs = 0,0011). Conclusiones: Se encontró heterogeneidad clínica y bajo nivel de evidencia publicada. La GFC fue considerable con el implante…


Objectives: To review and summarize indications, audiological and quality of life (QOL) outcomes of Carina® fully implantable device. Design: Systematic review. Methods: We conducted a systematic search of literature between June/2011 and January/2012 in: Medline, OVID, Embase, ProQuest, Cochrane Library. The unpublished information gray literature databases (Sigle) were also reviewed. No language or time limit restriction. Study eligibility criteria were: human studies with measures before and after the intervention. One patient case report and prelingual patients studies were excluded. Statistical heterogeneity was assessed (Der Simonian- Laird test), random effects model as a method of synthesis of functional gain was used. Publication bias was assessed (funnel plot and Eggs test). Results: 155 publications were identified, 43 of them were focused on the research topic, eight met the inclusion/exclusion criteria and report 110 patients. The pooled functional gain was 27.24 dB [95% CI = 21.66-32.83 dB], I2 = 85%. The word recognition (65 dB-SPL) was increased between 35%-70% with Carina®. A QOL improvement was observed (APHAB scale). The most frequent complication was device extrusion (3.6%). Publication bias was found (Eggs = 0.0011). Conclusions: Clinical heterogeneity and low evidence level were found in the published literature. The pooled functional gain was considerable with the implant. …


Subject(s)
Humans , Quality of Life , Cochlear Implantation , Hearing Loss, Conductive , Hearing Loss, Functional
11.
Acta otorrinolaringol. cir. cabeza cuello ; 40(4): 293-300, 2012. ilus
Article in Spanish | LILACS | ID: lil-692124

ABSTRACT

Objetivo: Describir la experiencia y comparar los resultados audiométricos y cambio en calidad de vida en pacientes con el dispositivo auditivo totalmente implantable Carina®. Diseño: Estudio antes y después. Métodos: El dispositivo Carina® fue implantado en pacientes con hipoacusia conductiva, mixta o neurosensorial de moderada a severa. Como método de evaluación se realizaron medidas repetidas intra-sujetos para ganancia funcional y cambios en calidad de vida. Se usó la prueba T-Student para muestras relacionadas en el análisis estadístico. Resultados: Se incluyeron 27 pacientes (edad media = 28,2±15,8 años). No se observaron diferencias significativas entre el promedio de tonos puros (PTP) de la vía ósea prequirúrgica y posquirúrgica (p > 0,05). La ganancia funcional media fue = 24,0 ± 7,9 dB; se encontró una diferencia estadísticamente significativa entre el PTP sin Carina® (62,3 ± 12,4 dB) y con Carina® (38,3 ± 11,9 dB) (p < 0,0001). Hubo una mejoría significativa en la calidad de vida con el uso del dispositivo (p < 0,05). Se presentó una explantación como única complicación mayor (3,7%). Conclusiones: Los resultados audiológicos y de cambios en calidad de vida encontrados muestran a Carina® como una opción de rehabilitación auditiva eficiente…


Objective: To describe implantation experience and compare audiometric outcomes and quality of life changes in patients with fully implantable hearing device Carina®. Design: Before-and-after study. Methods: Carina® hearing device was implanted in patients with conductive, mixed and sensorineural hearing losses. As assessment method repeated-measures withinsubjects for functional gain and quality of life changes were performed. The T-test for paired samples was used for statistical analysis. Results: 27 subjects were included (mean age = 28.2 ± 15.8). No significant differences were found between preoperative and postoperative bone conduction pure tone average (PTA) (p > 0.05). The mean functional gain was 24.0 ± 7.9 dB, significant differences between the unaided PTA (62.3 ± 12.4 dB) and aided PTA (38.3 ± 11.9 dB) were found (p < 0.0001). There was a significant improvement in quality of life with the device (p < 0.05). As a major complication, only one patient was explanted (3.7%). Conclusions: The audiological outcomes and quality of life changes show Carina® as an efficient option for hearing rehabilitation. …


Subject(s)
Humans , Quality of Life , Cochlear Implants , Prostheses and Implants , Hearing Loss
12.
Article in Spanish | LILACS | ID: lil-598145

ABSTRACT

Se reporta el caso de un schwanoma del nervio facial que compromete el nervio desde la porción laberíntica hasta la intraparotídea, con erosión de la cápsula ótica a nivel de la cóclea y función facial normal. Mediante decompresión nerviosa se logró preservación de las funciones facial y auditiva y a los 20 meses posoperatorios no hay evidencia de crecimiento tumoral. Se discuten las diferentes alternativas terapéuticas para aquellos casos con función facial y coclear normales.


This report describes a patient with a large facial nerve schwannoma, which involves the facial nerve from its labyrinthine portion until its intra parotid portion with normal facial function. There was also a mild erosion of the otic capsule. It was treated with nerve decompression with facial function andhearing preservation after two years of follow up.


Subject(s)
Facial Nerve/abnormalities , Facial Nerve/surgery
13.
Acta otorrinolaringol. cir. cabeza cuello ; 36(4): 205-215, dic. 2008. graf
Article in Spanish | LILACS | ID: lil-522594

ABSTRACT

La construcción de una base de datos es un aspecto importante durante la realización de una investigación. Aunque hay varios programas que permiten construir bases de datos, sugerimos utilizare paquetes estadísticos que provean el armamentario bioestadístico necesario para hacer los posteriores análisis. El programa SPSS es uno de los que tienen mayor acogida y es fácil de manejar, por ello lo utilizamos para los ejemplos. Antes de comenzar a construir la base de datos es muy importante determinar el nivel de medición de la variables, ya que de ello depende en gran parte el tipo de pruebas estadísticas que se van a utilizar. Hay cuatro tipo de variables de acuerdo al nivel de medición: nominales, ordinales, interválicas y proporcionales. Para las variables nominales y ordinales se utilizan pruebas no paramétricas; mientras que para las interválicas y proporcionales se utilizan pruebas paramétricas. Se describe paso a paso cómo ingresar una variable nominal y una variable proporcional, haciendo énfasis en aspectos de formato del paquete estadístico. Se hacen varias recomendaciones para sacar el máximo provecho a la base de datos.


A database construction is an important step in research development. Although several software packages permit you to building a database, we would suggest you to use a statistics software packages that supply you with biostatistics options to do any wished analysis. SPSS software package has wide reception and is easy to run, for that reason we used it for the following examples. Before anything else, to determine measurement level of study variables it is a central point, which is the main determinant to select a statistic test. Four variables are described according to measurement level: nominal, ordinal, interval and ratio variables. For nominal and ordinal variables non-parametric tests are used; otherwise, interval and ratio variables are analyzed with parametric tests. Step by step instructions to enter nominal and ratio variables are described; format topics of software package are highlighted. Some recommendations for maximum advantage of database are outlined.


Subject(s)
Data Analysis , Statistics, Nonparametric , Methodology as a Subject , Research Design